IPStrada’s multi-storied; 72,000 sq. ft. state-of the-art facility was constructed with the vision of providing world class colocation services, unmatched by any other. Over the last decade, IPStrada has proved this vision to be a reality by guaranteeing our customers the highest level of security monitoring, reliability, redundancy, and connectivity. Companies that choose IPS for their colocation needs can be rest assured that our technical experts are on location 24/7/365, safeguarding their equipment and ensuring continued uptime.

Technical Specifications:
• Full fledged Telco hotel
• Geographically 30 Miles apart from Dallas – Ideal location for backup and disaster recovery.
• Commercial grade 408 v 3 phase power throughout building
• Building connected to 3 separate grids for redundant power
• A+B+C power sources to protect against power outage, especially in the event of natural disasters.
• Power capacity to provide 500+ watts per square foot
• 1000+ Tons of cooling capacity
• 12 carriers, including Tier I providers
• 42 Points of fiber entry from 3 separate directions (East, West, and North) and more than 8000 strands of fiber.
• Multi story, telecom building to accommodate racks and private suites
• Ability to provide a full fledged turn key data center
• Complete concrete building built to withstand 200lbs per square foot
• 3 Tiers of security including biometric scanning
• Building monitored 24/7 by more than 42 CCTV camera
• No third party between customers and their equipment
• Access to over 300+ carriers
• Choose from top of the line carriers who provide service directly into the building, including: Verizon, AT&T, Qwest, XO Communications, Fiber Light, and many, many, more.

Location:
515 Houston Street
Fort Worth, Texas 76102
From Airports – 13 miles to Dallas/Fort Worth International Airport (DFW) : 25 miles to Dallas Love Field (DAL)
Parking – Adjacent Building Parking Available / Multiple Garage Parking Options

Profile:
Phone – 352-537-8652 (USA or Canada)
Email – info@IPStrada.net

Power:
Electrical Capacity-Starting at 4 kW per cabinet (Higher Density Options Available)
UPS Configuration-< N+1 block redundant system>
# of Utility Feeders-3
# of Power Transformers-3
Utility Voltage-480 V, 3-phase
Standby Power-One 2,000 MW diesel engine-generator power
Standby Power Config-

Cooling:
Cooling Plant-Chilled water, air handling units
Cooling Configuration-N+1 redundant

Security:
Physical-Key Code Access Required to enter Floor(Man trap/biometrics in lobby)
Electronic-CCTV and recorders, Biometric hand scan, badge readers

Building
Building Type-Multi-story, Concrete:
Floor Load Capacity-200 PSF

Significant Building Dates:
Year Base Building Constructed-1930
Year Base Building Retrofitted-1997
Year The Colocation Facility (Floor 3) Constructed-1998

Fire Protection:
Fire Suppression-Double-interlocked, pre-action (dry pipe)
Fire Rating-Minimum 2-hour rating

Interconnection Options:
System-Overhead cable tray system with multi-tier ladder rack
Cross Connects Available-Single-mode fiber, multi-mode fiber (62.5 and 50 micron), CAT5, CAT6, CAT5(T1), and CAT3 (POTS)
Carriers Available-AT&T, Verizon, TW Telecom, Qwest, AboveNet, XO, Fiberlight and Hurricane Electric (HE). (Level 3 Pending)